{{offlineMessage}} Try Microsoft Edge, a fast and secure browser that's designed for Windows 10 Get started Store Store home Devices Microsoft Surface PCs & tablets Xbox Virtual reality Accessories Windows phone Then, I copied the file Foo.exe to a Windows Server 2003 Enterprise Edition Service Pack 2. x 2 EventID.Net From a support forum: "When trying to diagnose Side-by-Side errors, start the SxSTracing using the following command: SxsTrace Trace -logfile:SxsTrace.etl Then run your application that is causing the Related Articles, References, Credits, or External Links NA Author: Migrated Share This Post On GoogleFacebookTwitter Subscribe to Newsletter Search for: Copyright PeteNetLive © 2016 current community chat Stack Overflow Meta Stack have a peek here

Comments to the question by Hans Passant and Luke helped. Event Type: Error Event Source: SideBySide Event Category: None Event ID: 32 Date: 09.01.2008 Time: 13:31:53 User: N/A Computer: HOSTNAME Description: Dependent Assembly Microsoft.VC80.MFCLOC could not be found and Last Error x 3 Justin Laing In my case, the error "Activation context generation failed for C:\Windows\system32\conhost.exe" related to Windows update KB2507938. Thank you for sharing this.

Then I copied the whole project to B. intelligence agencies claim that Russia was behind the DNC hack? Reference error message: The referenced assembly is not installed on your system.

Login here! x 2 EventID.Net From a support forum: "The program/module specified in the event was C:\Windows\WinSxS\amd64_microsoft.vc80.mfc_1fc8b3b9a1e18e3b_8.0.50727.762_none_c46a533c8a667ee7\MFC80.DLL - I uninstalled and reinstalled my backup software and it seems to have fixed the problem." The rest was a matter of searching for the right vcredist_x86.exe which happened to be in the URL I have mentioned in the second paragraph. This shouldnot have an impact on the software running properly.Regards,Rick B. 0 Kudos Reply Follow Siemens PLM Software siemens.com/plm © 2017 Siemens Product Lifecycle Management Software Inc Corporate Information Privacy Policy

I have elaborated it in my answer to my own question below. –Susam Pal Jan 19 '12 at 14:09 add a comment| 7 Answers 7 active oldest votes up vote 41 more hot questions question feed lang-cpp about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation What is the role of Side-by-Side? It didn't help as well.

Copying CRT DLLs and manifest from the Windows XP machine (where I built the EXE) didn't fix it. Temporary fix Comments APAR Information APAR numberIC57803 Reported component nameTDP FOR DOMINO Reported component ID5698DPDAP Reported release55W StatusCLOSED PER PENoPE HIPERNoHIPER Special AttentionNoSpecatt Submitted date2008-09-04 Closed date2008-09-04 Last modified date2008-09-04 APAR Why leave magical runes exposed? Dependent Assembly Microsoft.VC80.MFC,processorArchitecture="amd64",publicKeyToken="1fc8b3b9a1e18e3b",type="win32",version="8.0.50608.0" could not be found.

I removed this update to solve problem. http://www.eventid.net/display-eventid-33-source-SideBySide-eventno-10671-phase-1.htm TheEventId.Net for Splunk Add-onassumes thatSplunkis collecting information from Windows servers and workstation via the Splunk Universal Forwarder. Assembly: Microsoft.Windows.SystemCompatible This problem can occur when you have version 5.2.3790.2426 or a more recent version of the Winlogon.exe program installed. Concepts to understand: What is the role of Side-by-Side?

Three years later, and you solved my exact issue! –Carl Kevinson Nov 9 '15 at 21:16 add a comment| up vote 4 down vote Here is how you fix this issue: navigate here Now, I have added a note about processor architecture in my answer to this question. –Susam Pal Nov 22 '12 at 5:51 add a comment| up vote 3 down vote You The installer created a folder called: C:\windows\winsxs\x86_Microsoft.VC80.CRT_1fc8b3b9a1e18e3b_8.0.50727.762_x-ww_6b128700. Suppose we have given workspace with project A and active debug configuration giving not working application.

Beware when you run installer with "remove" option you came to previous situation. x 12 EventID.Net Assembly: Microsoft.Windows.Common-Controls See ME841082 for a hotfix applicable to Windows Server 2003 64-Bit Edition. Referenceerror message: The referenced assembly was not installed in your system"etc,etc,etc!These errors are duplicated every time SolidEdge free2d is started. Check This Out Mine was located at Mine was located at C:\Foo\Release\Foo.exe.intermediate.manifest.

This question has already been answered 5 months ago. –Susam Pal May 17 '12 at 18:41 add a comment| up vote 3 down vote I had a somewhat related problem. Login here! As MS prohibits distribution of debug versions of supporting dlls, "redistributable packages" won't install them. (Note that the assembly id depends on current subversion of VS2005 and is related to installed

read more...

In the deep past application authors just copied required dll's into system directories. Event ID: 32 Source: SideBySide Source: SideBySide Type: Error Description:Dependent Assembly could not be found and Last Error was: English: This information is only available to subscribers. Event ID: 59; Source: SideBySide Generate Activation Context failed for C:\foo\Foo.exe. I copied msvcm80.dll, msvcp80.dll and msvcr80.dll from C:\winnt\winsxs\x86_Microsoft.VC80.CRT_1fc8b3b9a1e18e3b_8.0.50727.762_x-ww_6b128700 of Windows XP machine (where I developed and built foo.exe) to C:\foo of Windows Server 2003 (where I am trying to run foo.exe).

MS then came up with with versioning idea (winsxs). Tried to run and got the same error messages mentioned by SusamPal. Build options In case, it helps you to answer my question. http://smartnewsolutions.com/event-id/microsoft-event-id-2019.html I got the same error.

When I tried to run it, it failed with this error, C:\foo.exe The application has failed to start because the application configuration is incorrect. Would more Full Nodes help scaling and transaction speed? share|improve this answer edited Jun 29 '15 at 3:41 Andrei Bârsan 2,2301831 answered Jun 28 '15 at 13:00 user5058117 11 1 Could you add some line breaks? The easiest way to figure this version was by looking at the manifest file generated by Visual Studio while building my project on the development system.

Not the answer you're looking for? Copying the DLLs and manifest files from the C:\Program Files\Microsoft Visual Studio 8\VC\redist\x86\Microsoft.VC80.CRT folder of the development machine fixed it. MFCLOC is not being installed properly when SolidEdge 2D Drafting V19 is installed. Follow the steps to download the Visual C++ Redistributables and then remove and reinstall Sage Line 50 2007.

Exactly the same VS2005 on Each. –user1752563 Nov 11 '15 at 12:11 add a comment| up vote 3 down vote Although my application was developed on Win 2k8 R2 x64 with up vote 34 down vote favorite 16 Issue I wrote a C++ project called 'Foo' using Microsoft Visual Studio 2005 Verison 8.0.50727.762 (SP.050727-7600) on Windows XP Professional Version 2002 Service Pack Built there. Event ID: 34; Source: SideBySide Component identity found in manifest does not match the identity of the component requested Event ID: 58; Source: SideBySide Syntax error in manifest or policy file

There could be many reasons why a file would be missing: applications that are uninstalled and remove some files that are used by other applications, still on that system, hardware problems So, yes, 8.0.50727.6195 was the version of the CRT DLLs I was looking for as Hans Passant rightly said. x 14 John Goulden This event occurs in conjunction with EventID 59 from source SideBySide and it is caused by an application that was not packaged with all of the necessary Dependent Assembly PDR.X, type="win32", version="1.0.0.0" - We opened the ":\Program Files\CyberLink\PhotoDirector\Kernel\CES\CES_AudioCacheAgent.exe.Manifest" file in Notepad and noticed that PDR.X was specified as a dependent assemby:

TheEventId.Net for Splunk Add-onassumes thatSplunkis collecting information from Windows servers and workstation via the Splunk Universal Forwarder. For more information, see Help and Support Center at [Microsoft Link] Event Type: Error Event Source: SideBySide Event Category: None Event ID: 59 Date: 09.01.2008 Time: 13:31:53 User: N/A Computer: HOSTNAME Thanks for help, tracking those versions isn't easy... –m_gol Nov 6 '12 at 9:49 Thank you so much for this! Why didn't Dumbledore appoint the real Mad Eye Moody to teach Defense Against Dark Arts?

Reply Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Subscribe Printer Friendly Page All Forum Topics Previous Topic Next I downloaded Microsoft Visual C++ 2005 Service Pack 1 Redistributable Package MFC Security Update and installed it on the system where I was trying to run C:\foo\foo.exe.